L
INE
C
OMMANDS
4-21
Default Setting
8 data bits per character
Command Mode
Line Configuration
Command Usage
The databits command can be used to mask the high bit on input
from devices that generate 7 data bits with parity. If parity is being
generated, specify 7 data bits per character. If no parity is required,
specify 8 data bits per character.
Example
To specify 7 data bits, enter this command:
Related Commands
parity (4-21)
parity
This command defines the generation of a parity bit. Use the no form to
restore the default setting.
Syntax
parity {none | even | odd}
no parity
none - No parity
even - Even parity
odd - Odd parity
Default Setting
No parity
Command Mode
Line Configuration
Console(config-line)#databits 7
Console(config-line)#